Martindale CM100 Flex Meter - CANS LTD

Martindale CM100 Flex Meter

CALL FOR PRICE

Description

The new CM100 True RMS current meter is fitted with a highly flexible current sensor 8.5mm in diameter, ideal for measurements on difficult sizes and shapes of conductors in hard to reach areas where conventional clamps won’t go.

The TRMS capability ensures accurate and reliable AC current measurement for distorted waveforms caused by today’s power electronics and non-linear loads.

Measurements are accurate and reliable with 3 ranges up to 3000A AC and resolution of 10mA in the 30A range. The light weight flexible sensor head will accommodate conductors up to 160mm in diameter and can be threaded through small apertures. Unlike conventional current transformers there is no maximum overload limitation.

The separate display module is fitted with a 1.8m lead giving even more freedom when working in areas with restricted access and is backlit for viewing in low light conditions. The Hold function can be used for saving displayed values and for longer term monitoring, the auto power off function can be easily disabled and Min/Max values recorded.

The CATIV 600V safety rating make the flex meter ideal for utility and industrial current measurement applications.

The CM100 is supplied with alkaline batteries and manual. All Martindale clamp meters come with a 2 year warranty.

Video

Specifications

 

AC current 30.00A/300.0A/3000A
Accuracy ± 3.0% ± 5 dgt (45Hz to 500Hz)
Flexible sensor length 458mm
Flexible sensor diameter 8.5mm
Max conductor 160mm diam.
Display cable length 1.8m
Sampling rate 2/sec.
Operating environment 0°C to 50°C <80% RH, non condensing
Storage temperature -10°C to 60°C, 70% RH
Complies with BS EN 61010-1

 

BS EN 61010-2-032

Class II

Double Insulation

600V CAT IV

EMC BS EN 61326-1

Pollution degree 2
Features Low battery indication, Auto power off/disable
Supply 2 x 1.5 V AAA batteries
Battery life 120 hrs typical alkaline
Weight 286g approx. incl batteries
Dimensions 120 x 70 x 26 mm
Includes 2 x 1.5V AAA alkaline batteries and manual


Comparison

  CM95 CM100 CMi210
AC Current
DC Current
AC/DC Volts
Ohms
Frequency
Capacitance
Non-contact Voltage Detector
Auto ranging
Max Conductor Size 85mm Ø 160mm Ø 55mm Ø
70x18mm
True RMS
Min Max
Backlight
Auto Power Off
Other Flexible
1mA resolution
Flexible
High current to 3000A
50-1000V Insulation Test
Temperature
Low Pass Filter
Safety CAT IV 600V CAT IV 600V CAT IV 600V

Datasheet

Download

 

Manual

Download