Kane 457 - CANS LTD

Kane 457

CALL FOR PRICE

KANE457
 

KANE457

Unique - ambient & flue CO2 in one analyser Ideal for commercial catering & incident investigations

Features

  • Rotary switch for ease of use
  • Logs & prints reports with optional infra-red printer
    • Combustion
    • Pressure
    • Let-by & Tightness
    • Temperature
    • CO & CO2 build up
    • Logs & prints ambient CO & CO2
  • 5 year warranty if serviced annually by Kane
KANE457 rgb
KANE457 IN HAND
KANE457 BASE rgb
KANE457 COMBUSTION TEST 1
KANE457 COMBUSTION TEST 2
KANE LIVE LAPTOP
KANE457 PRINT-OUT AMBIENT CO CO2 rgb
KANE457 PRINT-OUT ROOM AIR
KANE457 PRINT-OUT COMBUSTION
KANE457 PRINT-OUT TIGHTNESS
KANE457 PRINT-OUT TIMED LOG
KANE457 AGSM Winner
KANE457 WITH CO2-TRUE ZERO CAPSULE FITTED

Application

  • Installation, commissioning & servicing of domestic oil or gas appliances
  • Commercial Catering
  • Safety checks
    • CO in a room or around an appliance
  • Combustion performance checks
  • Combustion efficiency checks
  • Flue Draught
  • CMDDA1
  • Indoor Air Quality

Measures

  • CO2 direct with an infra-red sensor 0-20%
  • CO2 ppm 0-10,000ppm
  • CO 0-2,000ppm
  • Differential temperature
  • High accuracy differential pressure meter +/-80mbar

Calculates

  • O2
  • CO/CO2 ratio
  • Excess air
  • Combustion efficiency

Fuel Types

  • Natural Gas
  • Butane
  • Propane
  • LPG
  • 28 sec oil
  • 35 sec oil
  • Wood pellets

Box Contents

  • Analyser
  • Probe
  • Pressure connectors
  • CO2 true zero capsule
  • Charger
  • Manual
  • Calibration report

Specifications

Parameter Range Resolution Accuracy
Flue Temperature 0-600°C 0.1°C ±2.0°C
±0.3% reading
Inlet Temperature
(Internal Sensor)
0-50°C 0.1°C ±1.0°C
±0.3% reading
Inlet Temperature
(External Sensor)
0-600°C 0.1°C ±2.0°C
±0.3% reading
Oxygen*2 0-21% 0.1% ±0.3%*1
Carbon monoxide 0-20ppm
21-2000ppm nom
4,000ppm max for 15 mins
1ppm ±0.3%*1
±3ppm
±5% reading
Carbon dioxide 0-20% 0.1% ±0.3% reading
Efficiency (Net or Gross)*2 0-99.9% 0.1% ±1.0% reading
Effeciency High (C)*2 0-119.9% 0.1% ±1.0% reading
Excess Air*2 0-250% 0.1% ±0.2% reading
CO/CO2 ratio *2 0-0.999 0.0001 ±5% reading
Nominal range ±160mBar
Maximum over range without damage to sensor is ±800mBar
±0.2mBar
±1 mBar
±160mBar
Maximum
0.001 mBar
<25 mBar
±0.005 mBar
±0.03 mBar
±3% of reading
Pre-programmed Fuels Natural gas, Propane, Butanem LPG, Light Oils (28/35 sec), Wood Pellets
Ambient Measurements
Carbon Monoxide
As above
Carbon Dioxide 0 to 5000ppm 1ppm ±5% reading
5001 to 9999ppm 5ppm ±8%reading
Storage Capacity 99 Combustion tests
20 Pressure tests
20 Tightness tests
20 Temperature tests
20 Room CO tests
20 Ambient tests
up to 240 times tests (one sequence only)

*1 Using dry gases at STP
*2 Calculated

Ambient Operating Range Temperature - 0°C to 40°C
Humidity - 10% to 90% RH non-condensing
Atmospheric Pressure - 860 to 1060hPa
Battery Type / Life 4AA cells
>8 hours using Alkaline AA cells
Chargers (optional) 220v charger, for NiMH batteries only
12v in vehicle charger, for NiMH batteries only
Dimensions Weight - 0.8kg handset with protective cover
Handset - 200 x 45 x 90mm
Probe - 300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m neoprene hose. Type K thermocouple

Wireless Options

Optional wireless upgrade

  • Transfer analyser readings to your PC using a KANE LIVE software.
  • Send printout data to your mobile device using the free Kane printer app.
option.name

BTM/450

Wireless android module

option.name

BTM/450LE

Wireless iOS module

Kit Options

option.name

KIT

KANE IRP-2 Infra-red printer & carry bag

option.name

PRO KIT

As KIT plus GLD/450plus gas leak detector, KAL1 air liquid temperature probe, pressure hose & 2 x KPCP clamp-on pipe temperature probes and carry bag.

option.name

COM-CAT KIT

As KIT plus DAFM3 digital air flow meter.

option.name

CPA1 KIT

As PRO KIT plus ASP2 appliance sampling probe kit, 12v in vehicle charger, in a large carry bag.

option.name

CMDDA1 KIT

As KIT plus KANE77 personal CO monitor and CPS1 combustion probe stand.

Videos

1 - KANE457 Introduction

1 - KANE457 Introduction

2 - KANE457 Switch On

2 - KANE457 Switch On

3 - KANE457 Combustion Analysis

3 - KANE457 Combustion Analysis

4 - KANE457 Differential Pressure & Temperature

4 - KANE457 Differential Pressure & Temperature

5- KANE457 Ambient Air Testing

5- KANE457 Ambient Air Testing

How to change graphs - KANE LIVE

How to change graphs - KANE LIVE

How to change parameters - KANE LIVE

How to change parameters - KANE LIVE

How to change the header - KANE LIVE

How to change the header - KANE LIVE

How to change user details - KANE LIVE

How to change user details - KANE LIVE

How to change viewable readings - KANE LIVE

How to change viewable readings - KANE LIVE

How to connect supported bluetooth - KANE LIVE

How to connect supported bluetooth - KANE LIVE

How to download logs - KANE LIVE

How to download logs - KANE LIVE

How to pair and connect the KANE457 - KANE LIVE

How to pair and connect the KANE457 - KANE LIVE

How to save data - KANE LIVE

How to save data - KANE LIVE

How to use change the language - KANE LIVE

How to use change the language - KANE LIVE

How to use help - KANE LIVE

How to use help - KANE LIVE

How to use the pump functions - KANE LIVE

How to use the pump functions - KANE LIVE

KANE IRP-2 Changing the Printer Roll

KANE IRP-2 Changing the Printer Roll

Using the KANE Wireless Printer Android app

Using the KANE Wireless Printer Android app

Service Price

YEAR 1 YEAR 2 YEAR 3 YEAR 4 YEAR 5
£94 £94 £94 £94 £155

Rolling warranty ends after 6 years & becomes limited to replaced parts (12 months)


Calibration or Conformity Certificates are included in all prices, as appropriate

All prices are in £ sterling and are exclusive of VAT.

Software

Install

KANE Wireless Printer (Android app)

Install

KANE Wireless Printer - iPad App

Install

KANE Wireless Printer - iPhone App

Install

KANE LIVE