Fluke 1663
Fluke 1663 Multifunction Installation Tester Includes:
- 6x AA (IEC LR6) cell batteries
- C1600 hard carrying case
- Zero adapter
- Heavy duty mains cord
- STD standard test lead set
- Padded carrying and waist strap
- Quick reference guide
- TP165X remote control probe and lead
- User's manual on CD-ROM
- FREE Traceable Calibration Certificate
The versatility of the Fluke Multifunction Tester
Insulation-continuity test: our installation tester does the job.
Fluke installation testers can be used to perform an insulation-continuity test, which is designed to diagnose and prevent the breakdown of the insulation in various parts of the electrical system such as wires, transformers and motors. The quality of insulation is critical to assure proper, uninterrupted and safe functioning of electrical circuits.
Checking RCD devices with a Fluke multifunction tester.
Our versatile installation testers can also check the proper functioning of residual-current devices (RCDs). RCDs are designed to disconnect quickly to mitigate the harm caused from electric shock and to avoid current leaks that may lead to fire and other dangerous situations. Our installation testers assure that RCDs can properly perform this important task.
The perfect loop testing tool: a Fluke installation tester.
Loop testing is a quick, convenient, and highly specific method of evaluating an electrical circuit for its ability to engage protective devices (circuit breakers, fuses, RCDs). A ground loop determines the effectiveness of protective devices.
Resistance measurement of grounding systems.
The electrical installation testing abilities of the Fluke installation tester also include verification tests to ensure that a system's resistance is low enough to provide protection to people, equipment and structures. A properly functioning grounding system is a critical safety feature of an electrical system.
Measurement functions
- Continuity at L-N, N-PE inputs
- Test smooth dc sensitive RCDs (Type B)
- Earth resistance
- Voltage & frequency
- Wiring polarity checker, detects broken N wires
- Insulation resistance
- Continuity & resistance
- Measure motor windings with continuity test
- Loop & line resistance
- Prospective earth fault current (PEFC/IK)
- Prospective short-circuit current (PSC/IK)
- RCD switching time
- RCD tripping level (ramp test)
- Measures trip time & current for RCD type A & AC in one test
- RCD variable current
- Automatic RCD test sequence
- Phase sequence indicator
Other features
- On/Off switchable auto-start for RCD & looptest
- Self-test
- Illuminated display
Memory interface
- Z Max Memory
- Memory
- Computer Interface (when used with optional FlukeView & Fluke DMS software)
- Time and date (when used with optional FlukeView software)
Fluke 1660 Series Comparison Guide
Which is the right model for me?
The new Fluke 1660 Series Multifunction Installation Testers are the only installation testers that help prevent damage to connected appliances, while allowing users to wirelessly e-mail results from the field. Auto Test does all required installation tests in one sequence, ensuring compliance with local installation regulations.
Old Model |
New Model |
Features Changes – What’s New |
1651 |
1662 |
|
1652 |
1662 |
|
1653 |
1663 |
|
1654 |
1664 FC |
|
Measurement Function |
1664 FC |
1663 |
1662 |
Insulation-PreTest™ safety function New |
* |
|
|
Insulation at L-N, N-PE and L-PE inputs New |
* |
|
|
Automatic test sequence New |
* |
|
|
Loop and line resistance–mΩ resolution |
* |
|
|
Continuity at L-N, N-PE and L-PE inputs New |
* |
* |
|
Test smooth dc sensitive RCDs (Type B) |
* |
* |
|
Earth resistance |
* |
* |
|
Voltage (True-rms) and frequency |
* |
* |
* |
Wiring polarity checker, detects broken PE and N wires |
* |
* |
* |
Insulation resistance Continuity and resistance |
* |
* |
* |
Measure motor windings with continuity test (@ 10 mA) |
* |
* |
* |
Loop and line resistance |
* |
* |
* |
Prospective earth fault current (PEFC/IK) |
* |
* |
* |
Prospective short-circuit current (PSC/IK |
* |
* |
* |
RCD switching time |
* |
* |
* |
RCD trip time |
* |
* |
* |
RCD trip current (ramp test) |
* |
* |
* |
Measures trip time and current for RCD type A & ac in one test |
* |
* |
* |
RCD variable test current |
* |
* |
* |
Automatic RCD test sequence |
* |
* |
* |
Phase sequence test |
* |
* |
* |
Other features |
|
|
|
Fluke Connect Compatibility New |
* |
|
|
ShareLive™ Calling New |
* |
|
|
FlukeCloud™ Storage New |
* |
|
|
On/Off switchable auto-start for RCD and loop test New |
* |
* |
* |
Self-test |
* |
* |
* |
Illuminated display |
* |
* |
* |
Memory, interface |
|
|
|
Z max memory New |
* |
* |
|
Memory |
* |
* |
|
IR-USB and BLE interface (use with optional Fluke DMS and FVF software) |
IR-USB/BLE |
IR-USB |
|
Included accessories |
|
|
|
Heavy duty, single input line cord New |
* |
* |
* |
Hard case |
* |
* |
* |
Remote control probe |
* |
* |
* |
Zero adapter |
* |
* |
* |