Fluke 1760 Three Phase Power Quality Recorder
Class-A compliance for the most demanding power quality tests
The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and low-voltage networks, this power quality monitor provides the flexibility to customize thresholds, algorithms, and measurement selections. The 1760 power recorder captures the most comprehensive details on user-selected parameters.
Key Features:
-
Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
-
GPS time synchronization: Correlate data with events or datasets from other instruments with precision
-
Flexible and fully configurable thresholds and scale factors: Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.
-
Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages to help determine the cause
-
10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
-
2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
-
Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
-
Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries
-
Rugged field design: Insulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions
Product Feature |
Fluke 1760 Basic |
Fluke 1760TR Basic |
Fluke 1760 |
Fluke 1760TR |
Power quality statistics according to EN50160 |
● |
● |
● |
● |
Voltage event list (dips, swells and interruptions) |
● |
● |
● |
● |
Continuous recording of: |
Voltage |
● |
● |
● |
● |
Current |
● |
● |
● |
● |
Power P, Q, S |
● |
● |
● |
● |
Power factor |
● |
● |
● |
● |
kWh |
● |
● |
● |
● |
Flicker |
● |
● |
● |
● |
Unbalance |
● |
● |
● |
● |
Frequency |
● |
● |
● |
● |
Voltage and current harmonics to the 50th / Interharmonics |
● |
● |
● |
● |
THD |
● |
● |
● |
● |
Mains signaling |
● |
● |
● |
● |
Triggered recordings |
● |
● |
● |
● |
Online mode (Oscilloscope, transients and events) |
● |
● |
● |
● |
Fast transient analysis up to 10 MHz |
|
● |
|
● |
4, 600V voltage probes |
|
|
● |
● |
4 dual-range flexible current probes (1000 A / 200 A ac) |
|
|
● |
● |
GPS time sync receiver |
|
|
● |
● |
Memory |
2 GB Flash memory |
Typical Applications:
Detailed disturbance analysis – Perform high-speed transient analysis and uncover root cause of equipment malfunction for later mitigation and predictive maintenance. The fast transient option, with its 6000 V measurement range, allows capture of very short impulses such as lightning strikes.
Class-A quality-of-service compliance – Validate incoming power quality at the service entrance. Thanks to Class A compliance, the Fluke 1760 allows undisputable verification.
Event correlation at multiple locations – Utilizing GPS time synchronization, users can quickly detect where a fault occurred first, either inside or outside the facility.
Galvanic separation and DC coupling – Allows complete measurements on dissimilar power systems. For example troubleshoot UPS systems by simultaneously recording the battery voltage and power output.
Power quality and power load studies – Assess baseline power quality to validate compatibility with critical systems before installation and verify electrical system capacity before adding loads.
Model Name |
Description |
Fluke 1760 Basic |
Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:
- Internal Flash-memory 2 GB
- PQ Analyze software on CD-ROM
- Ethernet cable for network connection (1)
- Crosslink Ethernet cable for direct PC connection (1)
- Mains cable (1)
- Operational manuals
- Carrying bag
|
Fluke 1760TR Basic |
Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:
- Internal Flash-memory 2 GB
- PQ Analyze software on CD-ROM
- Ethernet cable for network connection (1)
- Crosslink Ethernet cable for direct PC connection (1)
- Mains cable (1)
- Operational manuals
- Carrying bag
- Fast transient analysis up to 10 MHz
|
Fluke 1760 |
Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:
- Internal Flash-memory 2 GB
- PQ Analyze software on CD-ROM
- Ethernet cable for network connection (1)
- Crosslink Ethernet cable for direct PC connection (1)
- Mains cable (1)
- Operational manuals
- Carrying bag
- Voltage probes, qty 4 (600 V for INTL set, 1000 V for US set)
- Current probes, qty 4 (Dual-range flexible current probes 1000 A / 200 A AC)
- GPS time sync receiver
|
Fluke 1760TR |
Power Quality Recorder Topas with 8 input-channels (4 currents/4 voltages or 8 voltages) Includes:
- Internal Flash-memory 2 GB
- PQ Analyze software on CD-ROM
- Ethernet cable for network connection (1)
- Crosslink Ethernet cable for direct PC connection (1)
- Mains cable (1)
- Operational manuals
- Carrying bag
- Fast transient analysis up to 10 MHz
- Voltage probes, qty 4 (600 V for INTL set, 1000 V for US set)
- Current probes, qty 4 (Dual-range flexible current probes 1000 A / 200 A AC)
- GPS time sync receiver
|